Product Description
The new generation of SeQual Eclipse raises the bar for POC performance. The Eclipse 5 features the same benefits that you love about the Eclipse 3, but with next generation internal components that enhance the reliability of the POC. The Eclipse 5 goes where you go, with improved DC power operation that allows for full functionality of the Eclipse 5 when running from DC outlets. All continuous flow settings, up to 3 LPM, as well as all pulse flow settings, including the largest super setting of 192 mL, are now available while operating on both AC and DC power. The Eclipse 5 battery will also charge when the unit is connected to DC power while operating at all flow settings up to 2.0 LPM.
The Highest Pulse Dose Oxygen Output of ANY POC:
The SeQual Eclipse delivers the highest pulse dose oxygen output of any portable oxygen concentrator on the market. Offering pulse dose settings from 1 to 9, the Eclipse 5 is capable of supporting even the traditionally most difficult to treat patients. The Eclipse pulse settings 1-6 are increased in 0.5 increments, rather than in increments of 1.0, giving patients and providers additional flexibility when selecting a pulse dose setting. The additional super-bolus pulse settings, settings 7-9, are adjustable in 1.0 increments until reaching the 9 setting at 192 mL per pulse dose. No other POC on the market can match the extreme pulse dose oxygen output of the Eclipse 5.
If you’re currently delivering cylinders and have high delivery costs, look no further because Eclipse 5 is the ultimate solution for your patients and your business. Save time and money because cylinder deliveries are eliminated. Most patients not only require oxygen at home, but also on the go – SeQual Eclipse acts as both a stationary and portable unit to meet these needs.
Features
- NEW: All continuous flow and pulse dose volumes available while operating on DC power
- NEW: Battery cartridge will re-charge when unit is connected to DC power for all continuous flow settings up to 2.0 LPM and all pulse flow settings 1 to 9
- NEW: Next generation internal components enhance unit reliability
- Approved for Rx of 0.5 - 3.0 LPM continuous flow
- Pulse dose settings 1 to 9 deliver a bolus from 16mL to 192mL
- autoSAT Technology helps maintain a consistent FiO2 by servo-controlling the device to meet the patients changing respiratory rate
- Three available rise time options—Fast, Medium, and Slow
- Three Adjustable Pulse Dose sensitivity settings
- Innovative Universal Cart design allows for easy access to battery
- AC and DC adapters that are smaller in size, yet more durable
- In Pulse Dose Mode, if an inspiratory effort is not detected, the device will deliver a continuous flow of oxygen; continually searching for a breath every 15 seconds.
PRODUCT SPECIFICATIONS |
|
Size (H x W x D): |
19.3 x 12.3 x 7.1 inches 49.0 x 31.2 x 18.0 cm |
Weight: |
Eclipse: 15.0 lbs Power Cartridge: 3.4 lbs |
Continuous flow settings |
0.5 to 3.0 LPM (0.5 liter increments) |
Pulse Dose Settings |
16-96 (16mL increments), 128mL, 160mL, 192mL |
Oxygen concentration |
90% ± 3% @ sea level |
Oxygen output pressure |
5.0 psig (34.5 kPa) nominal |
Sound level |
48 dB(A) at 3.0 LPM continuous flow 40 dB(A) at 3.0 Pulse Dose setting |
POWER SPECIFICATIONS |
|
AC Operation |
100 - 240 VAC, 50 - 60 Hz |
DC Operation |
12 V nominal |
Power Cartridge |
Quantity (2) 97.5 W-Hr battery packs each containing 7.92 grams of equivalent lithium content |
Power Consumption |
52 watts at 1.0 LPM continuous flow 145 watts at 3.0 LPM continuous flow 45 watts at 1.0 pulse flow setting 95 watts at 6.0 pulse flow setting |
Nominal Power Cartridge operating time |
2.0 hours at 2.0 LPM continuous flow 1.3 hours at 3.0 LPM continuous flow 5.2 hours at 2.0 pulse flow setting, 12 bpm 3.5 hours at 6.0 pulse flow setting, 12 bpm |
Power Cartridge recharge time |
1.8 to 5.0 hrs, dependent upon the flow setting, to achieve80% capacity from a fully discharged Power Cartridge |
Back up alarm power |
9 Volt battery |
Oxygen concentrationindicator |
Green Light = Normal Operation Red Light Flashing = Abnormal Operation |
Operating temperature |
50° F to 104° F (10° C to 40° C) 82.4° F (28° C) dew point, non-condensing |
Trigger sensitivity |
Adjustable between -0.25 cm H2O to -0.7 cm H2O |
Altitude operating range |
0-13,123 feet (0-4000 meters) |
* Specifications subject to change without notice